+91 84259 01234

Call for any Support

Vasai - 401208, India

Main Office location
Laboratory Ovens - Xpert Scientific Private Limited

Laboratory Ovens

NRS_1826_oven_with_open_doors

A. Specifications:

 

Model GMP & Standard
Temperature Range +10°C above
Temperature Accuracy ± 0.5°C
Temperature Uniformity ± 1.5°C
Size

Available in standard or can be tailor made to suit your specific requirements

 

B. Common Features:

Standalone Chamber Construction:

  • 75mm thick PUF Insullattion with SS skin on both side
  • Inner SS 304 Mirror & Outer SS 304 Matt finish or Powder Coated
  • Perforated tray with unique tray arrangement
  • Metal Door with Gasket & latch on outside
  • Force air circulation for uniform Temperature.
  • SS U shape tubular air heater
  • PU castor wheels for ease of movement

Software:

  • Full filling the requirement of 21 CFR part 11 compliance
  • Automatic backup facility
  • Passwaord reset & expiry
  • All user’s activities are tracable in Audit Trails
  • Mean Kinetic Temperature Calculations
  • Data export in pdf format
  • Data Trends

PLC Base Control System:

  • Chamber operation control through PLC,
  • PID Auto Tune Facility

 

HMI (TSD):

  • Human Machine Interface ( Touch Screen Display)
  • All operational setting done through 4.3” TFT LCD with LED Backlight
  • Inbuilt Data storage facility.
  • Adjustable data interval timing.
  • Off line Printing
  • Password Protection

Sensor:

  • High quality Temperature  sensor
  • Fast Response time
  • Low drift

Alarms/Event:

  • Temperature deviations
  • Mains Failure
  • Temperature Overshoot
  • Chamber Shutdown
  • Door Opening

Safety:

  • Temperature Overshoot/Undershoot
  • MCB for overload 

Door Access:

  • Password protected door access through HMI
  • Restrict unauthorised person to access the chamber

Mobile Alert (GSM):

  • Time of alarm
  • Equipment Name
  • Type of Alarm

Documentation:

  • IQ, OQ & PQ
  • Material test certificate
  • Calibration Certificate (Through NABL Lab)
  • Operation Manual
  • Maintenance Manual
  • Drawing Electrical, General Assembly & Mapping Positions
  • Training to chamber handling user

Scanner:

  • 4 temp probe can be installed to map the condition in various location of the chamber
  • Excellent uniformity

C. Chamber Size

XPERT CHAMBER SIZES
MODEL CAPACITY LTRS DIMENSION IN CM TRAY SIZE TRAY
INTERNAL EXTERNAL
W D H W D H
XSO0K100 100 45 40 56 59.5 76 110 42X37X1.5 6
XSO0K200 200 60 60 60 75 105 117 57X57X1.5 7
XSO0K325 324 60 60 90 75 105 147 57X57X1.5 10
XSO0K400 400 60 60 112 75 105 169 57X57X1.5 13
XSO0K500 500 70 71.5 100 85 116.5 157 67X68.5X1.5 12
XSO0K600 600 70 71.5 120 85 116.5 177 67X68.5X1.5 14
XSO0K800 800 80 83.5 120 95 138.5 177 77X77X1.5 14
XSO0001K 1000 80 83.5 150 95 138.5 212 77X77X1.5 18